Please refer to the following table.

If you have any questions, please don’t hesitate to contact us.

Strength Quality Standard of COMPLITE
property unit condition COMPLITE®
107 107C 108 108C
Bendable strength Pa N/mm2 A 225 137 201 118*
Pe N/mm2 A 216 137 196 118*
Bending elasticity
coefficient
Pa kN/mm2 A 20.6 12.3 18.6 10.8*
Pe kN/mm2 A 18.6 12.3 17.2 9.8*
Compression strength Pa N/mm2 A 196 147 172 123*
Pe N/mm2 A 118 255 98 230*
Compression elasticity
coefficient
Pa kN/mm2 A 10.8 6.9 8.8 5.9*
Pe kN/mm2 A 2.5 2.9 1.8 2.0*
Shear strength Pa N/mm2 A 20.6 15.2 17.6 12.7*
(Bar) Shear strength PaPe N/mm2 A 74* 49* 69* 44*
Cleavage strength Pa N/mm2 A 69*

1) *Reference value 2) Pa:Parallel to the lamination 3) Pe:Perpendicular to the lamination

Lower limit of electric properties for COMPLITE
property unit condition COMPLITE®
107 107C 108 108C
Electric
properties
Withstand voltage
vertical to layer
(1 min.)
20°C kV/mm H:24hr/105°C O:0.5hr/20°C 10 10 10 10
Edgewise withstand
voltage
(1 min.)
20°C kV/mm H:24hr/105°C
O:0.5hr/20°C
10 10 10 10
Insulation resistance Normalcy A 10 10 10 10
Inundation D:24hr/20°C 10 10 1 1